This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
Allow all cookies
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Decline all cookies
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
SPC5330.320-L1 Einbruchmeldezentr.,G3
If you are a registered Vanderbilt partner, please log in to see pricing.
Not a Vanderbilt customer? No problem, you can register here.
Need a Vanderbilt product installer? click here
Not a Vanderbilt customer? No problem, you can register here.
Need a Vanderbilt product installer? click here
- Article number: V54541-C107-B100
- EAN/UPC-Code: 4025515470748
Product information "SPC5330.320-L1 Einbruchmeldezentr.,G3"
The SPC5330.320 control panel combines in an optimal way intrusion and
access functionality in one system and can be expanded according to
specific customers and project needs with up to 128 zones (8 on-board),
128 outputs (6 on-board), 16 system keypads, 8 door controllers, 8
verification zones. The controller provides 2 X-BUS ports (2 stubs or 1
loop), 16 areas, 500 users with different access levels, memory for
10’000 intrusion and 10'000 access events, integrated Web Server, 2
terminals for the pluggable PSTN and GSM/GPRS communication options, on-
board Ethernet interface. The system is expandable with 2-way wireless
receivers and supports up to 64 Intrunet wireless detectors (mixed with
wired zones). The panel comes in a tamper protected and hinged metal
housing with space for optional 17 Ah battery and 4 additional
expanders.
- Certificate (CE) - Issued by Vanderbilt, on 07/09/2020
- Certificate - Issued by CNPP, on 23/11/2021
- Certificate - Issued by IMQ, on 04/02/2015
- Certificate - Issued by Telefication, on 18/12/2020
- Certificate - Issued by INCERT, on 14/12/2020
- Certificate - Issued by SBSC, on 01/01/2021
- Certificate - Issued by SBSC, on 01/01/2021
- Certificate - Issued by SBSC, on 17/12/2019
- Certificate - Issued by SBSC, on 17/12/2019
- Certificate - Issued by SBSC, on 29/09/2021
- Certificate - Issued by SBSC, on 29/09/2021
- Certificate - Issued by VdS, on 29/11/2019
- Certificate - Issued by VSÖ, on 06/08/2019
- Certificate - Issued by KVALITET, on 06/05/2019
- Certificate (PD6662) - Issued by Vanderbilt, on 25/02/2022
- Certificate (PD6662) - Issued by Vanderbilt, on 29/03/2019
- Certificate (MSDS) - Issued by Supplier, on 10/01/2020
- Certificate (UN38.3) - Issued by Supplier, on 19/12/2019
- Certificate - Issued by CNPP, on 02/11/2022
- Certificate - Issued by SBSC, on 20/02/2023
- Certificate - Issued by SBSC, on 20/02/2023
Door capacity: | Max. 16 entry doors or 8 entry/exit doors |
Quiescent current: | Max. 170 mA at 12 VDC |
Output voltage: | 13-14 VDC in normal conditions (mains powered and fully charged battery) |
Operating temperature: | 0 ~ +40 °C |
Weight: | 6.400 kg |
Housing: | Hinged metal housing (1.2 mm mild steel) |
Power output: | Max. 750 mA bei 12 VDC |
Remote controls: | Up to 50 |
Max. number of hardwired zones: | 128 |
Verification: | 8 verification zones with max. 4 IP-cameras and 8 audio devices. |
Mains voltage: | 230 VAC, + 10%/ -15%, 50 Hz |
Video: | Up to 16 pre / 16 post event images (by JPEG resolution 320 x 240, max. 1 frame / sec.) |
IP-Communication: | Yes |
Language: | Multi-language support (en + 4 imported language files).Available language files: de, en, es, fr, it, nl, sv. |
Approval: | EN50131-1 / EN50131-3 / EN50131-6, Grade 3, Class IIUK: PD6662:2010BE: INCERTSE: SFF1014, Larmklass 2 |
Max. number of wireless zones: | 64 (take away wired zones) |
Firmware: | 3.8.5 |
Operating current: | Max. 190 mA at 12 VDC |
Tamper contact: | Front spring tamper, back tamper, 1 auxiliary tamper contact input |
Interfaces: | 2 X-BUS (2 spurs or 1 loop), 2 RS232, 1 USB (PC connection), 1 SPC Fast Programmer, 1 Ethernet (RJ45) |
Colour: | RAL 9003 (signal white) |
Event memory: | 10'000 intrusion events, 10'000 access events |
Number of on-board zones: | 8 |
EOL resistor: | Dual 4K7 (default), other resistor combinations selectable |
Number of on-board relays: | 1 strobe (30 VDC / 1 A resistive switching current) |
Audio: | Up to 60 sec. pre / 60 sec. post audio recording |
Dimensions (W x H x D): | 326 x 415 x 114 (mm) |
- Datasheet - (English) - SPC5330.320-L1 Intrusion CP,G3
- Datasheet - (German) - SPC5330.320-L1 Intrusion CP,G3
- Datasheet - (French) - SPC5330.320-L1 Intrusion CP,G3
- Datasheet - (Spanish) - SPC5330.320-L1 Intrusion CP,G3
- Datasheet - (Swedish) - SPC5330.320-L1 Intrusion CP,G3
- Wiring - (German) - spc4xxx5xxx6xxxwiring
- Wiring - (English) - spc4xxx5xxx6xxxwiring
- Wiring - (Spanish) - spc4xxx5xxx6xxxwiring
- Wiring - (French) - spc4xxx5xxx6xxxwiring
- Wiring - (Italian) - spc4xxx5xxx6xxxwiring
- Wiring - (Dutch) - spc4xxx5xxx6xxxwiring
- Wiring - (Swedish) - spc4xxx5xxx6xxxwiring
- Installation Manual - (English) - 220_SPC Install and Config_A6V10276959-h_EN
- Installation Manual - (German) - 220_SPC-Install-and-Config_A6V10276959-g_DE
- Installation Manual - (French) - SPC Install and Config_A6V10316314-g_FR
- Planning guide - (Multilingual) - SPC Matrix 3.13.7_EN
- Planning guide - (French) - SPC Matrix 3.13.7_FR
- Planning guide - (Italian) - SPC Matrix 3.13.7_IT
- Product Support Guide - (English) - EOL Bands in SPC
- Product Support Guide - (English) - SPC Camera Integration
- Product Support Guide - (German) - TAS link III EDP Integration in SPC Anleitung
- Product Support Guide - (English) - SPC Eventys IPC Integration
- Product Support Guide - (German) - Aufschaltung SPC EDP (Certas Schweiz)
- Product Support Guide - (English) - SPC Panel FW SW Overview
- Product Support Guide - (English) - SMS Setup SPC
- Product Support Guide - (English) - SPC Connect Setup
- Product Support Guide - (English) - SPC Video Verification
- Product Support Guide - (English) - SPC XBus Wiring
- Product Support Guide - (English) - SPC Connect Trouble Shooting
- Product Support Guide - (French) - Câblage sirène sur SPC
- Product Support Guide - (French) - Câblage XBus sur SPC
- Product Support Guide - (French) - Connexion centrale SPC Connect 3G
- Product Support Guide - (French) - Connexion centrale SPC Connect
- Product Support Guide - (French) - Connexion Web SPC Chrome
- Product Support Guide - (French) - Connexion Web SPC IE
- Product Support Guide - (French) - Connexion Web SPC Firefox
- Product Support Guide - (French) - Configuration Calendrier SPC
- Product Support Guide - (French) - Création login SPC Connect Pro
- Product Support Guide - (French) - Enrolement badges SPC
- Product Support Guide - (French) - Configration levée de doute audio video SPC
- Product Support Guide - (French) - Création secteur commun SPC
- Product Support Guide - (French) - Test entrées sorties SPC
- Product Support Guide - (French) - Test transmission SPC
- Product Support Guide - (English) - SPC Firmware 3.11 Upgrade Dialer Delay
- Product Support Guide - (Danish) - SPC Firmware 3.11 Upgrade Dialer Delay
- Product Support Guide - (English) - SPC over fibre
- Product Support Guide - (German) - Ausgang setzen über Bedienteil
- Product Support Guide - (English) - SPC and HIK-Vision Camera
- Product Support Guide - (Danish) - SPC og Milesight kamera
- Product Support Guide - (English) - SPC Connect V3.0 - Password Recovery
- Product Support Guide - (Spanish) - SPC a traves Fibra
- Product Support Guide - (English) - SPC Connect Pro Data Migration
- Product Support Guide - (English) - SPC Connect Pro - Upgrade Issue
- Product Support Guide - (English) - SPCN340 Signal Information Guide
- Product Support Guide - (English) - Factory and users reset
- Product Support Guide - (French) - Restauration d’Usine et des Utilisateurs
- Product Support Guide - (French) - Configuration FlexC SPC Connect en Ethernet et Modem pour SPC
- Product Support Guide - (English) - E-Bus with SPC
- Product Support Guide - (Swedish) - E-Bus med SPC
- Product Support Guide - (English) - Web browser compatibility with SSL/TLS1.2
- Application Note - (German) - Gen2 an SPC
- Application Note - (English) - FDX60M1 Fiber Multimode to X Bus SPC
- Application Note - (English) - SPC XBus integration Expander
- Application Note - (English) - GM730 an SPC VDS
- Application Note - (English) - GM775 an SPC VDS
- Application Note - (German) - Hotkey Prox an SPC
- Application Note - (English) - ECO560 wiring to SPC
- Application Note - (German) - ECO560 an SPC
- Software - (English - Version 02) - SPC Power Calculation V3.0
- Software - (German - Version 01) - SPC Stromberechnung V3.0
- Firmware - (Multilingual - Version ) - SPC Firmware 3.14.1_20230904
- Firmware - (Multilingual - Version ) - SPC Firmware 3.14.5_20240819_Installer package
- Software - (Multilingual - Version 01) - SPC Connect Pro - Configuration Tool