This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
Configuration
Technically required
These cookies are necessary for the basic functions of the shop.
Allow all cookies
CSRF token
Cookie preferences
Currency change
Customer recognition
Customer-specific caching
Decline all cookies
Individual prices
Selected shop
Session
Comfort functions
These cookies are used to make the shopping experience even more appealing, for example for the recognition of the visitor.
Note
Statistics & Tracking
Affiliate program
Track device being used
SPC6330.320-L1 Intrusion CP,G3
If you are a registered Vanderbilt partner, please log in to see pricing.
Not a Vanderbilt customer? No problem, you can register here.
Need a Vanderbilt product installer? click here
Not a Vanderbilt customer? No problem, you can register here.
Need a Vanderbilt product installer? click here
in stock
Ready to ship
Delivery time appr. 1-3 workdays
- Article number: V54541-C105-C100
- EAN/UPC-Code: 4025515470724
Product information "SPC6330.320-L1 Intrusion CP,G3"
The SPC6330.320 control panel combines in an optimal way intrusion and access functionality in one system and can be expanded
according to specific customers and project needs with up to 512 zones (8 on-board), 512 outputs (6 on-board), 32 system keypads,
64 doors, 16 verification zones. The controller provides 2 X-BUS ports (2 stubs or 1 loop), 60 areas, 2500 users with different
access levels, memory for 10’000 intrusion and 10'000 access events, integrated Web Server, 2 terminals for the pluggable PSTN and
GSM/GPRS communication options, on-board Ethernet interface. The system is expandable with wireless receivers and supports up to
120 Intrunet wireless detectors (mixed with wired zones). The panel comes in a tamper protected and hinged metal housing with space
for optional 17 Ah battery and 4 additional expanders.
Quiescent current: | Max. 170 mA at 12 VDC |
Door capacity: | Max. 64 entry doors or 32 entry/exit doors |
Verification: | 16 verification zones with max. 4 IP-cameras and 16 audio devices. |
Video: | Up to 16 pre / 16 post event images (by JPEG resolution 320 x 240, max. 1 frame / sec.) |
Audio: | Up to 60 sec. pre / 60 sec. post audio recording |
Interfaces: | 2 X-BUS (2 spurs or 1 loop), 2 RS232, 1 USB (PC connection), 1 SPC Fast Programmer, 1 Ethernet (RJ45) |
Tamper contact: | Front spring tamper, back tamper, 1 auxiliary tamper contact input |
Mains voltage: | 230 VAC, + 10%/ -15%, 50 Hz |
Operating current: | Max. 190 mA at 12 VDC |
Output voltage: | 13-14 VDC in normal conditions (mains powered and fully charged battery) |
EOL resistor: | Dual 4K7 (default), other resistor combinations selectable |
Operating temperature: | 0 ~ +40 °C |
Weight: | 6.400 kg |
Housing: | Hinged metal housing (1.2 mm mild steel) |
Approval: | EN50131-1 / EN50131-3 / EN50131-6, Grade 3, Class II UK: PD6662:2010 BE: INCERT SE: SFF1014, Larmklass 2 |
Power output: | Max. 750 mA bei 12 VDC |
IP-Communication: | Yes |
Number of on-board relays: | 1 strobe (30 VDC / 1 A resistive switching current) |
Max. number of wireless zones: | 120 (take away wired zones) |
Max. number of hardwired zones: | 512 |
Colour: | RAL 9003 (signal white) |
Firmware: | V3.6 |
Remote controls: | Up to 100 |
Event memory: | 10'000 intrusion events, 10'000 access events |
Language: | Multi-language support (en + 4 imported language files). Available language files: de, en, es, fr, it, nl, sv. |
Number of on-board zones: | 8 |
Dimensions (W x H x D): | 326 x 415 x 114 mm |
- Datasheet (French) - spc6330
- Datasheet (Spanish) - spc6330
- Datasheet (English) - SPC6330
- Datasheet (Swedish) - SPC6330
- Datasheet (German) - SPC6330
- Wiring (German) - spc4xxx5xxx6xxxwiring
- Wiring (English) - spc4xxx5xxx6xxxwiring
- Wiring (Spanish) - spc4xxx5xxx6xxxwiring
- Wiring (French) - spc4xxx5xxx6xxxwiring
- Wiring (Italian) - spc4xxx5xxx6xxxwiring
- Wiring (Dutch) - spc4xxx5xxx6xxxwiring
- Wiring (Swedish) - spc4xxx5xxx6xxxwiring
- Installation instructions (Italian) - InstallAndConfig_PDF
- Installation instructions (Dutch) - InstallAndConfig_PDF
- Installation instructions (Danish) - InstallAndConfig_PDF
- Installation instructions (German) - InstallAndConfig_PDF
- Installation instructions (English) - InstallAndConfig_PDF
- Installation instructions (Spanish) - InstallAndConfig_PDF
- Installation instructions (French) - InstallAndConfig_PDF
- Installation instructions (Swedish) - InstallAndConfig_PDF
- Install manual (German) - spcfwsp42xx43xx52xx53xx63xxv3.6
- Install manual (English) - spcfwsp42xx43xx52xx53xx63xxv3.6
- Install manual (Spanish) - spcfwsp42xx43xx52xx53xx63xxv3.6
- Install manual (French) - spcfwsp42xx43xx52xx53xx63xxv3.6
- Install manual (Italian) - spcfwsp42xx43xx52xx53xx63xxv3.6
- Install manual (Dutch) - spcfwsp42xx43xx52xx53xx63xxv3.6
- Install manual (Swedish) - spcfwsp42xx43xx52xx53xx63xxv3.6