GB-5700-6 Glassbreak detector,6m,lam

If you are a registered Vanderbilt partner, please log in to see pricing.
Not a Vanderbilt customer? No problem, you can register here.
Need a Vanderbilt product installer? click here
  • V54535-F103-A200
  • 4025515478492
Product information "GB-5700-6 Glassbreak detector,6m,lam"
The glassbreak-detector is specially developed for working on laminated glass area within a radius of 2 m under surveillance. The glass break detector must be pasted at the pane of glass with glueset from LOCTITE (Accessories). Attention: Glueset differs from the glue dedicated to GB-5100 and GB-5300 Because the glass-surface is not plane, a surveillance of structure-glass is not possible. Also it is not allowed to use the glassbreak-detector on wired glass, because the wire netting is damping the mechanical oscillations. The detectors can be used in combination with the interface unit, GB-5000-IN, in bigger installations where you have to consider power consumption. It is possible to connect up to 20 detectors to one interface unit. Secondary Packaging: 25 Units
Gross weight (KG) 0.107
Purchase unit PCE
EAN/UPC-Code: 4025515478492
Minimum order 1
ECCN N
Material code V54535-F103-A200
Net weight 0.102
Statistical code 85311030
Country of origin DE
Quiescent current: ˂1 µA (ca. 20 nA)
Reset voltage: Max. 1 V
Current consumption, quiescent: ˂1 µA (ca. 20 nA)
Current consumption: 3.5 mA (6 VDC)
Supply voltage: 3 – 16 V DC
Environmental class: III
Housing protection: IP67
Housing material: S-B
Operating temperature: -25 ~ 70 °C
Cable length: 6 m
Approval: EN 50131-2-7-2, Grade 2