SPC4320.320-L1 Intrusion CP,G2
Not a Vanderbilt customer? No problem, you can register here.
Need a Vanderbilt product installer? click here
- Article number: V54541-C109-B100
- EAN/UPC-Code: 4025515470762
The SPC4320.320 control panel combines in an optimal way intrusion and access functionality in one system and can be expanded according to specific customers and project needs with up to 32 zones (8 on-board), 30 outputs (6 on-board), 4 system keypads, 4 doors, 4 verification zones. The controller provides 1 X-BUS ports (1 stub), 4 areas, 100 users with different access levels, memory for 1’000 intrusion and 1'000 access events, integrated Web Server, 2 terminals for the pluggable PSTN and GSM/GPRS communication options, on-board Ethernet interface. The system is expandable with 2-way wireless receivers and supports up to 32 Intrunet wireless detectors (mixed with wired zones). The panel comes in a tamper protected metal housing with space for optional 7 Ah battery and 1 additional expander.
- Certificate (CE) - Issued by Vanderbilt, on 07/09/2020
- Certificate - Issued by CNPP, on 23/11/2021
- Certificate - Issued by IMQ, on 04/02/2015
- Certificate - Issued by Telefication, on 18/12/2020
- Certificate - Issued by INCERT, on 14/12/2020
- Certificate - Issued by SBSC, on 17/12/2019
- Certificate - Issued by SBSC, on 29/09/2021
- Certificate - Issued by SBSC, on 29/09/2021
- Certificate - Issued by SBSC, on 01/01/2021
- Certificate - Issued by SBSC, on 01/01/2021
- Certificate - Issued by SBSC, on 17/12/2019
- Certificate - Issued by VdS, on 29/11/2019
- Certificate - Issued by VSÖ, on 06/08/2019
- Certificate - Issued by KVALITET, on 06/05/2019
- Certificate (PD6662) - Issued by Vanderbilt, on 29/03/2019
- Certificate (PD6662) - Issued by Vanderbilt, on 25/02/2022
- Certificate - Issued by CNPP, on 02/11/2022
- Certificate - Issued by SBSC, on 20/02/2023
- Certificate - Issued by SBSC, on 20/02/2023
Max. number of hardwired zones: | 32 |
Output voltage: | 13-14 VDC in normal conditions (mains powered and fully charged battery) |
Operating temperature: | 0 ~ +40 °C |
Power output: | Max. 750 mA bei 12 VDC |
Video: | Up to 16 pre / 16 post event images (by JPEG resolution 320 x 240, max. 1 frame / sec.) |
Tamper contact: | Front spring tamper, 2 auxiliary tamper contact inputs |
Weight: | 4.500 kg |
Approval: | EN50131-1 / EN50131-3 / EN50131-6, Grade 2, Class II UK: PD6662:2010 BE: INCERT SE: SFF1014, Larmklass 2 |
Remote controls: | Up to 32 |
Max. number of wireless zones: | 32 (take away wired zones) |
Operating current: | Max. 190 mA at 12 VDC |
Door capacity: | Max. 4 entry doors or 2 entry/exit doors |
Verification: | 4 verification zones with max. 4 IP-cameras and 4 audio devices. |
Interfaces: | 1 X-BUS (1 spur), 1 RS232, 1 USB (PC connection), 1 SPC Fast Programmer, 1 Ethernet (RJ45) |
IP-Communication: | Yes |
Language: | Multi-language support (en + 4 imported language files).Available language files: de, en, es, fr, it, nl, sv. |
Firmware: | 3.8.5 |
Dimensions (W x H x D): | 264 x 357 x 81 (mm) |
Event memory: | 1'000 access events |
Quiescent current: | Max. 170 mA at 12 VDC |
Mains voltage: | 230 VAC, + 10%/ -15%, 50 Hz |
Audio: | Up to 60 sec. pre / 60 sec. post audio recording |
Colour: | RAL 9003 (signal white) |
Number of on-board zones: | 8 |
EOL resistor: | Dual 4K7 (default), other resistor combinations selectable |
Number of on-board relays: | 1 strobe (30 VDC / 1 A resistive switching current) |
Housing: | SPC4320.320: Metal housing (1.2 mm mild steel) SPC4320.220: Metal base (1.2 mm mild steel), Plastic Lid (Polycarbonate) |
- Datasheet - (English) - SPC4320.320-L1 Intrusion CP,G2
- Datasheet - (German) - SPC4320.320-L1 Intrusion CP,G2
- Datasheet - (French) - SPC4320.320-L1 Intrusion CP,G2
- Datasheet - (Spanish) - SPC4320.320-L1 Intrusion CP,G2
- Datasheet - (Swedish) - SPC4320.320-L1 Intrusion CP,G2
- Wiring - (German) - spc4xxx5xxx6xxxwiring
- Wiring - (English) - spc4xxx5xxx6xxxwiring
- Wiring - (Spanish) - spc4xxx5xxx6xxxwiring
- Wiring - (French) - spc4xxx5xxx6xxxwiring
- Wiring - (Italian) - spc4xxx5xxx6xxxwiring
- Wiring - (Dutch) - spc4xxx5xxx6xxxwiring
- Wiring - (Swedish) - spc4xxx5xxx6xxxwiring
- Installation Manual - (English) - 220_SPC Install and Config_A6V10276959-h_EN
- Installation Manual - (German) - 220_SPC-Install-and-Config_A6V10276959-g_DE
- Installation Manual - (French) - SPC Install and Config_A6V10316314-g_FR
- Planning guide - (Multilingual) - SPC Matrix 3.13.7_EN
- Planning guide - (French) - SPC Matrix 3.13.7_FR
- Planning guide - (Italian) - SPC Matrix 3.13.7_IT
- Planning guide - (English) - Acre intrusion controllers technical specs matrix
- Planning guide - (English) - Acre Intrusion Controller power calculation tool_ Feb25
- Product Support Guide - (English) - Wiring RS485 twisted pair
- Product Support Guide - (English) - EOL Bands in SPC
- Product Support Guide - (English) - SPC Camera Integration
- Product Support Guide - (German) - TAS link III EDP Integration in SPC Anleitung
- Product Support Guide - (English) - SPC Eventys IPC Integration
- Product Support Guide - (German) - Aufschaltung SPC EDP (Certas Schweiz)
- Product Support Guide - (English) - SPC Panel FW SW Overview
- Product Support Guide - (English) - SMS Setup SPC
- Product Support Guide - (English) - SPC Connect Setup
- Product Support Guide - (English) - SPC Video Verification
- Product Support Guide - (English) - SPC XBus Wiring
- Product Support Guide - (English) - SPC Connect Trouble Shooting
- Product Support Guide - (French) - Câblage sirène sur SPC
- Product Support Guide - (French) - Câblage XBus sur SPC
- Product Support Guide - (French) - Connexion centrale SPC Connect 3G
- Product Support Guide - (French) - Connexion centrale SPC Connect
- Product Support Guide - (French) - Connexion Web SPC Chrome
- Product Support Guide - (French) - Connexion Web SPC IE
- Product Support Guide - (French) - Connexion Web SPC Firefox
- Product Support Guide - (French) - Configuration Calendrier SPC
- Product Support Guide - (French) - Création login SPC Connect Pro
- Product Support Guide - (French) - Enrolement badges SPC
- Product Support Guide - (French) - Configration levée de doute audio video SPC
- Product Support Guide - (French) - Création secteur commun SPC
- Product Support Guide - (French) - Test entrées sorties SPC
- Product Support Guide - (French) - Test transmission SPC
- Product Support Guide - (English) - SPC Firmware 3.11 Upgrade Dialer Delay
- Product Support Guide - (Danish) - SPC Firmware 3.11 Upgrade Dialer Delay
- Product Support Guide - (English) - SPC over fibre
- Product Support Guide - (German) - Ausgang setzen über Bedienteil
- Product Support Guide - (English) - SPC and HIK-Vision Camera
- Product Support Guide - (Danish) - SPC og Milesight kamera
- Product Support Guide - (English) - SPC Connect V3.0 - Password Recovery
- Product Support Guide - (Spanish) - SPC a traves Fibra
- Product Support Guide - (English) - SPC Connect Pro Data Migration
- Product Support Guide - (English) - SPC Connect Pro - Upgrade Issue
- Product Support Guide - (English) - SPCN340 Signal Information Guide
- Product Support Guide - (English) - Factory and users reset
- Product Support Guide - (French) - Restauration d’Usine et des Utilisateurs
- Product Support Guide - (French) - Configuration FlexC SPC Connect en Ethernet et Modem pour SPC
- Product Support Guide - (English) - E-Bus with SPC
- Product Support Guide - (Swedish) - E-Bus med SPC
- Product Support Guide - (English) - Web browser compatibility with SSL/TLS1.2
- Application Note - (German) - Gen2 an SPC
- Application Note - (English) - FDX60M1 Fiber Multimode to X Bus SPC
- Application Note - (English) - SPC XBus integration Expander
- Application Note - (English) - GM730 an SPC VDS
- Application Note - (English) - GM775 an SPC VDS
- Application Note - (German) - Hotkey Prox an SPC
- Application Note - (English) - ECO560 wiring to SPC
- Application Note - (German) - ECO560 an SPC