Product information "PDM-IXA18(50) Dual det. 10.525GHz 50pcs"
The PDM-IXx18 and PDM-IXx18T dual motion detectors offer reliable detection of intruders and high false alarm immunity. Their performance is based on an improved version of Vanderbilt`s Matchtec algorithm, which combines passive infrared (PIR) and microwave (MW) channels to make extraordinarily accurate decisions on motion within their detection zone. Intelligent processing routines analyse the relative strength of the IR and MW signals received from a moving object in order to make sound decisions. It is even possible to use multiple detectors in close proximity to each other, since the algorithm reduces interference between the MW modules. This increases flexibility in selecting the installation site. Flexible installations can be carried out quickly and error-free due to features like Auto Walktest and the new End-of-Line concept (EoL).
Gross weight (KG) 0.1
Purchase unit PCE
Minimum order 1
Statistical code 85311030
Country of origin RO
Net weight 0.100
ECCN EAR99
Material code L54531-S119-A100
Microwave (MW): 10.525 GHz
Air humidity (EN 60721): < 95% RH, non-condensing
Current consumption: 4.8 mA (rms) 9.0 mA (max peak)
Colour: RAL9003
Housing protection: IP41 / IK02
EOL resistor: RI = 4.7 kΩ ±5%, 250 mW RF = 2.2 kΩ ±5%, 250 mW REoL = 4.7 kΩ ±5%, 250 mW
Operating temperature: - 10° ~ + 55°C
Sensitivity evaluation mode: 6 settings
Approval: EN50131-2-4 grade 2
Storage temperature: - 20° ~ + 60°C
Detection characteristics / range: Volumetric / 18 m
Dimensions (W x H x D): 64 x 147 x 35 (mm)
Pet immunity: yes (option)
Set/unset input: LOW ≤ 1,5 V / HIGH ≥ 3,5 V RPull-up (internal) = 470 kΩ
Walking speed: 0.2 ~ 3.0 m/s / 0.2 ~ 3.0 m/s
Walk test input: LOW ≤ 1,5 V / HIGH ≥ 3,5 V RPull-up (internal) = 470 kΩ
Supply voltage: 9 ~ 16 VDC (12 V nom.)
Optical system: MAGIC mirror
Weight: 0.12 kg